Featured post

Loop Detector Installation - Common Mistakes to Avoid

Loop detector installation is essential in any facility, whether for commercial or residential use. In addition to choosing the appropriate model, it's also important to follow the proper procedures. This article will cover the installation process and common mistakes to avoid. First, ensure that the lead-in wires are twisted 6 turns per foot. If they are larger than that, they will trip the detector, resulting in repeated service calls and repeat visits.

Ensure the loop is protected from weather by properly connecting the wires to the loop. This includes using a special sealant to protect the wires and lead-in cable. Sealants come in many forms, and the right type will depend on your specific situation. You should read the manufacturer's instructions before choosing a material for the wiring. You can purchase these materials online or from a local electronics store. It's important to remember that the wiring should be properly protected.

The wires must be securely sealed to prevent moisture from penetrating the sealant. The sealant should be applied so that it fills the sawcut, but does not overfill. The sealant should also be placed slightly below the surface of the pavement and a trowel should be used to remove any excess sealant. If any of these steps is not followed, you may end up with a poorly installed detector. For example, a poorly installed loop detector may be overfilled and not be completely sealed. Another common mistake is not sealing the entire surface with the sealant. The result can be an uneven surface and air bubbles in the sealant.

For a permanent installation, you must cut the loop with a masonry cutting disc. A 45deg crosscut will reduce the risk of damaging the loop wire insulation. When the wires are properly installed, you can install the inductive loop detector. This installation procedure is relatively easy and straightforward and can be done by a single worker. The installation process should only take a few hours, and it can be completed in less than one day.

The backer rod and loop wires need to be securely fastened. The backer rods should be sealed with a sealant that can withstand a temperature of 350 degrees F. A sealed backer rod will ensure that the wires are completely protected. Using the ULTRAMETER will help you understand how the wires are being installed and optimize sensitivity. If you want to install a vehicle detector, make sure the wiring is properly insulated.

The backer rod material used for an inductive loop detector should be resistant to heat. The backer rod should be cut at the same time as the wire. If the backer rod is made of PVC, you should not use it for this purpose. It is likely to melt. In case you have to fix the wires, you should hire a professional. It's not hard to do, but the process will require some work.

Inductive-loop detectors should be installed correctly. Its installation should be thorough and uncomplicated. The backer rod should not be more than three inches wide, but the loop must be in the same plane as the vehicle. Moreover, the backer rod material should be protected by a layer of insulation. The inductive-loop wires are very sensitive, and you should never expose it to extreme heat. The wires that are not insulated will not detect the vehicle.

Inductive-loop detectors need to be installed with caution. Choosing the right wire size is essential, but the material and thickness of the wires are not critical. Besides, make sure that you protect them with a protective coating before laying them in the street. Moreover, you should use a conductive tape to avoid tripping hazards. Inductive-loop detectors must be installed with care.

While the installation of inductive-loop detectors is relatively easy, it must be installed with caution. A high failure rate can cause the installation to fail. Induced-loop detectors need to be installed carefully. The inductive-loop wires should be covered with hot asphalt to prevent damage from it. Regardless of the material, you must protect the wiring from the heat. You should make sure that the installers are following the manufacturers' specifications and recommendations.

Comments